OECD TG 117

OECD TG 117, OECD Test Guidelines for the Testing of Chemicals, Section 1 (Physicochemical Properties), contains the standard ‘Partition coefficient (n-octanol/water), High-Performance Liquid Chromatography (HPLC) method’, i.e. the standard Partition coefficient (n-octanol/water), High-Performance Liquid Chromatography (HPLC) method.

The partition coefficient (Kow or P) is a measure of the equilibrium distribution of a substance between the n-octanol and aqueous phases and is usually expressed as log Kow (log P).

This parameter is a fundamental indicator of a substance’s lipophilicity (fat solubility) and is of crucial importance for assessing its bioaccumulation potential, distribution in the environment and toxicokinetic behaviour.

OECD Test Guideline 117 is not based on the direct experimental determination of the log Kow value (OECD Test Guideline 107 – shaking flask, OECD Test Guideline 123 – slow stirring), but on an estimation based on the correlation between retention behaviour in the HPLC system and the log Kow value. The method is particularly suitable for substances with low water solubility and in cases where direct measurement is difficult.

The basic principle of the test is as follows:

  • The test substance and reference substances with known log Kow values are analysed using a standardised HPLC system.
  • The capacity factor (k′) is calculated for each substance:

k′ = (tR − t0) / t0

Here, tR is the retention time and t0 is the run-through time (the time taken by the component that is not retained).

  • A regression relationship is established between the known log Kow values of the reference substances and the measured log k′ values.
  • The measured k′ value for the test substance is substituted into this calibration equation to estimate the log Kow value.

The system components frequently used in this process are:

Pillar:

  • C18 (octadecyl) or C8 analytical columns with a bonded phase
  • The particle size of the column, its dimensions and the type of stationary phase must be kept constant and specified

Mobile phase:

  • Water/methanol or water/acetonitrile mixtures
  • As the composition and pH of the mobile phase directly influence the retention behaviour, they must be controlled and specified
  • In the case of ionisable substances, pH control is of crucial importance

Reference substances:

  • Substances for which log Kow values are known from reliable sources and which are chemically similar to the test substance
  • The log Kow values of the reference substances should be selected so that they cover the expected range of the test substance
  • As a rule, reference substances with a log Kow range between 0 and 6 are used

Detection:

  • UV-VIS detector, diode array detector (DAD) or other suitable detectors
  • Measurement of the test substance and the reference substances at a suitable wavelength and with sufficient sensitivity

The basic parameters specified in the study are:

  • log Kow
  • (log P)
  • Capacity factor (k′) and retention times (tR, t0)
  • Column used, composition of the mobile phase and pH value
  • Reference substances and their known log Kow values
  • Regression equation, correlation coefficient (r²) and scope of validity
  • Measured temperature
  • Data on measurement uncertainty and repeatability

Why is it carried out?

OECD TG 117 is being carried out for the following scientific and regulatory purposes:

  • Characterisation of lipophilicity: log Kow is a fundamental indicator of a substance’s fat solubility and its potential to cross cell membranes
  • Assessment of bioaccumulation potential: High log Kow values may indicate the substance’s tendency to accumulate in living tissue
  • Prediction of distribution in the environment: log Kow is used to predict the distribution of the substance in water, soil, sediment and biota
  • Toxicokinetic assessment: Used to predict the absorption, distribution, metabolism and excretion behaviour of a substance
  • Support with regulatory documentation: Used in environmental impact assessments under REACH, for plant protection products, biocides and medicinal products
  • Classification and labelling: The log Kow value is used in some regulatory frameworks to classify a substance’s environmental hazard potential
  • Preliminary assessment for screening purposes: Provides a quick and cost-effective preliminary estimate before resorting to direct measurement methods (TG 107, TG 123)
  • Input for model calculations: Used as the log Kow parameter in environmental fate and transport models
  • Quality control: Monitoring the consistency of the lipophilic behaviour of substances in production processes

OECD TG 117 allows for an estimate rather than a direct measurement. The results must be validated by direct measurement methods such as OECD TG 107 (shake-flask) or OECD TG 123 (slow-stirring), particularly where they are of critical importance for regulatory decision-making processes. The estimated values should be interpreted taking into account the chemical structure, the state of ionisation and the pH of the substance.

As part of our nano-testing services, we carry out log-Kow estimates in accordance with OECD TG 117, applying scientific rigour and utilising our accredited laboratory facilities and quality management system. Our scope of services includes the following:

Method selection and validation

  • Assessment of the applicability of OECD TG 117 based on the chemical properties of the test substance (polarity, ionisation, molecular size)
  • Selection of a suitable column (C18 or C8) and a mobile phase system
  • Selection of reference substances with known log Kow values that cover the expected range of the test substance
  • Derivation of the calibration equation, determination of the regression equation and the r² value
  • Validation of the method: linearity, accuracy, repeatability and inter-repeatability
  • Evaluation and reporting of measurement uncertainty
  • Documentation of method-specific limitations and conditions of use

For your log Kow estimates in accordance with OECD TG 117, you can contact Nano-Test to obtain information on the applicability of the method, the selection of reference substances, the validation of the HPLC system, sample acceptance criteria, the test schedule and the reporting procedures.