OECD TG 112
OECD TG 112 is the standard ‘Dissociation Constants in Water’, which is included in Section 1 (Physico-chemical properties) of the OECD Test Guidelines for the testing of chemicals. It was first adopted in 1981 and updated in 1995. It is not a test for health effects or ecotoxicity, but rather a test for determining physicochemical properties.
The dissociation constant (Ka) and its negative logarithm, the pKa value, are measures of a substance’s tendency to ionise in water. The pKa value determines the ratio of the substance’s ionised (anionic or cationic) form to its neutral form at a given pH value. Consequently, the pKa value is a fundamental physicochemical parameter, particularly for ionisable substances.
OECD TG 112 covers methods for determining the pKa value of ionisable substances. The basic principle of the test is to measure the ionisation equilibrium of the substance under controlled conditions and to calculate the pKa value. Common methods include:
Potentiometric titration:
- The sample is titrated with a standard acid or base, and the change in pH is monitored
- The pKa value is calculated from the titration curve
- Anwendbar über einen breiten pKa-Bereich; liefert insbesondere im Bereich pKa 2–12 zuverlässige Ergebnisse
- For substances with multiple ionisation stages, several pKa values can be determined
Spectrophotometric method (UV-Vis):
- The different absorption spectra of the ionised and neutral forms of the substance are utilised
- The pKa value is calculated by measuring the absorbance at different pH values
- Particularly suitable for substances that are poorly soluble or unsuitable for potentiometric titration
- Preferably used with substances containing chromophore groups
Conductometric method:
- The change in the solution’s electrical conductivity during titration is measured
- The pKa value is calculated from the change in conductivity caused by ionisation
- Particularly suitable for weak acids and bases
Other methods:
- Other validated techniques that have been calibrated using suitable reference substances (e.g. NMR titration, capillary electrophoresis)
- The choice of method is based on the solubility of the substance, its absorption properties and the number of ionisation stages
The key parameters reported in the study are:
- pKa value(s) (for each ionisation stage)
- Ka value(s)
- Measured temperature (°C)
- Ion strength and the electrolyte used
- Details of the method and equipment used
- Assignment of the corresponding pKa values in the case of multiple ionisation
- Data on measurement uncertainty and repeatability
Why is it carried out?
OECD TG 112 is being carried out for the following scientific and regulatory purposes:
- Ionisation characterisation: determining the pH range within which the substance is present in its ionised form, and the proportion in which it is present
- Predicting behaviour in the environment: The pKa value influences the ionisation state of the substance under pH conditions in the environment (soil, sediment, water) and thus its mobility, adsorption and bioavailability
- Interpretation of the distribution coefficient (log Kow): For ionisable substances, the log Kow value is pH-dependent; without knowing the pKa value, log Kow data cannot be interpreted correctly
- Interpretation of water solubility: The pKa value helps us to understand how the solubility of ionisable substances changes as a function of pH
- Design of ecotoxicity and toxicity tests: Provides guidance on the selection of test concentrations and pH conditions
- Toxicokinetic assessment: The substance’s ability to pass through cell membranes and its behaviour in biological systems depend on its degree of ionisation
- Assistance with regulatory documentation: The pKa value is used in environmental impact assessments under REACH, for plant protection products, biocides and medicinal products
- Classification and labelling: The pKa value is used in some regulatory frameworks to assess the physicochemical and ecological behaviour of a substance
- Input for model calculations: The pKa value is used as a parameter in models of environmental fate and transport
OECD Guideline TG 112 does not, in itself, constitute a toxicity or hazard assessment. It is intended for physicochemical characterisation; the results must be interpreted in conjunction with other physicochemical properties (log Kow, water solubility, adsorption), toxicological data and an exposure assessment.
As part of our nano-testing services, we carry out pKa determinations in accordance with OECD TG 112, applying scientific rigour and drawing on our accredited laboratory facilities and quality management system. Our scope of services includes the following:
Method selection and validation
Selection of the appropriate method (potentiometric titration, spectrophotometry, conductometry) in accordance with the properties of the test substance (solubility, absorption, degree of ionisation, pKa range) and the regulatory requirements
Validation of the selected method and verification using suitable reference substances (e.g. standards with a known pKa value); assessment and reporting of measurement uncertainty; documentation of method-specific limitations and conditions of use
Please feel free to contact Nano-Test for information on the choice of methods, sample acceptance criteria, the testing schedule and the reporting procedures for your pKa determinations in accordance with OECD TG 112.