OECD TG 104

OECD TG 104 is the standard “Vapour Pressure”, i.e. Vapour pressure, which are in Section 1 (Physical and chemical properties) is included in the OECD Test Guidelines for the testing of chemicals.

Vapour pressure is defined as the pressure exerted by the vapour phase in a closed system when the substance is in equilibrium between its solid and liquid states. It is usually expressed in Pa, hPa, kPa or mmHg and depends heavily on temperature. Vapour pressure is a fundamental indicator of a substance’s volatility.

OECD TG 104 permits the use of suitable methods for different vapour pressure ranges. Common methods include:

Static method:

  • In a closed system, an equilibrium is established between the substance and its vapour, and the total pressure is measured
  • Suitable for use across a wide pressure range; particularly suitable for substances with low vapour pressure

It can take a long time to reach equilibrium; the process is sensitive to impurities and gases

Dynamic process (gas transport / transpiration):

  • An inert carrier gas is passed through the sample at a controlled rate
  • The amount of substance transported by the carrier gas is determined analytically
  • Suitable for substances with low vapour pressure; achieving saturation is of crucial importance

Gas saturation process (Gas Saturation / Saturator):

  • The carrier gas is saturated with the sample, and the amount of substance transported is measured
  • Particularly suitable for substances with a very low vapour pressure
  • It is necessary to check the saturation and monitor the carrier gas flow rate

Isotenioscope/effusion procedure (Knudsen):

  • For solids with a low vapour pressure, the effusion of the vapour is measured through a small opening
  • Can also be used at very low pressures

Other procedures:

  • Other validated techniques that have been calibrated using suitable reference substances

The key parameters reported in the study are:

  • Vapour pressure (Pa, hPa, kPa or mmHg)
  • Measured temperature (°C)
  • Details of the method and equipment used
  • Where appropriate, measurements at different temperatures and temperature dependence
  • Data on measurement uncertainty and repeatability

Why is this being done?

OECD TG 104 is being carried out for the following scientific and regulatory purposes:

Characterisation of volatility: Vapour pressure is a fundamental indicator of a substance’s volatility and its tendency to transition into the vapour phase

Predicting environmental behaviour: Vapour pressure provides an indication of the substance’s potential for release into the atmosphere, its distribution in the environment and its fate

Exposure assessment: Vapour pressure is a key factor in assessing the potential for inhalation exposure

The relationship between the Henry’s constant and vapour pressure: in conjunction with water solubility, this is used to predict distribution in the environment

Classification and labelling: Vapour pressure is taken into account in the classification of chemical substances with regard to physical hazards, as well as in transport regulations

Input for further tests: Vapour pressure influences the design and dosing of ecotoxicity and toxicity tests

Quality control: Monitoring the consistency of raw materials, intermediate products and finished products in production processes

Weighing up the evidence: Contributes, together with other physico-chemical, toxicological and environmental data, to the holistic assessment of the substance

OECD TG 104 does not, in itself, constitute a toxicity or hazard assessment. It is intended for physicochemical characterisation; the results must be interpreted in conjunction with other physicochemical properties, toxicological data and the exposure assessment.

As part of our nano-testing services, we carry out vapour pressure measurements in accordance with OECD TG 104, applying scientific rigour and drawing on our accredited laboratory facilities and quality management system. Our scope of services includes the following:

Method selection and validation

Selection of the appropriate method (static, dynamic, gas saturation, Knudsen) in accordance with the expected vapour pressure range and the properties of the test substance

Validation of the selected method and verification using suitable reference substances; selection, calibration and determination of the limit of detection of the analytical measurement method (GC, HPLC, spectrophotometry, etc.)Assessment and reporting of measurement uncertainty; documentation of method-specific limitations and conditions of use

Please feel free to contact Nano-Test for information on the choice of methods, the analytical measurement strategy, sample acceptance criteria, the test schedule and the reporting procedures relating to your vapour pressure determinations in accordance with OECD TG 104.