CIPAC MT 53.3

CIPAC MT 53.3, a standardised physico-chemical test method published by the Collaborative International Pesticides Analytical Council (CIPAC) for determining the wettability of formulations in the form of wettable powder (WP). CIPAC is an international organisation that standardises analytical methods and physico-chemical test procedures for pesticide products; CIPAC methods are widely recognised in pesticide authorisation dossiers, product specifications and quality control processes.

Wettability is a measure of how long it takes for a powder formulation to become fully wetted upon contact with the water’s surface and to disperse in the water. The wetting time is a crucial performance parameter, ensuring that the product forms a homogeneous suspension when mixed with water and disperses evenly in the spray tank without clumping.

The basic principle of the test is as follows:

  • A specific quantity of the WP sample is carefully applied to a water surface at a standard temperature and hardness.
  • The time taken for the sample to become completely wetted on the water’s surface and to submerge is measured using a stopwatch.
  • The measured time is recorded as the wetting time and is usually expressed in seconds or minutes.
  • The test is carried out with a specified number of repetitions; the results are given as the mean and standard deviation.

The basic parameters specified in the study are as follows:

  • Wetting time (seconds or minutes)
  • Sample quantity and water volume
  • Water hardness (usually standard hardness) and temperature (°C)
  • Sample depth and method of feeding the sample to the water surface
  • Number of repetitions and mean/standard deviation of the results
  • Comparison with the specification value (if available)
  • Measurement uncertainty and repeatability data

Why is the test carried out?

CIPAC MT 53.3 is being conducted for the following scientific, technical and regulatory purposes:

  • Assessment of product performance: Determination of the WP formulation’s ability to wet rapidly and completely upon contact with water
  • Ensuring application quality: providing baseline data to reduce the risk of clumping, settling and blockages in the spray tank
  • Verification of compliance with the product specification: determining whether the wetting time corresponds to the specified value (e.g. maximum wetting time)
  • Quality control: Monitoring consistency between production batches and ensuring product quality
  • Formulation development: Optimisation of the selection of wetting agents, dispersants and excipients
  • Assessment of storage stability: Monitoring whether wettability is maintained after ageing
  • Support with regulatory documentation: Use in authorisation dossiers for plant protection products (e.g. EU Regulation 1107/2009, national regulations) and in product specifications
  • Approach to assessing evidential value: a contribution to the holistic evaluation of the product in conjunction with other formulation tests (suspension capacity, spreading time, sieve test, suspension stability, foaming), analytical data and stability studies

CIPAC MT 53.3 does not, in itself, provide comprehensive information on product quality or biological efficacy. It enables a physico-chemical performance assessment; the results should be interpreted in conjunction with other formulation tests, analytical data, stability studies and the requirements of the specifications.

As part of our nano-testing services, we carry out wettability tests in accordance with CIPAC MT 53.3 with scientific rigour, utilising our accredited laboratory facilities and quality management system. Our scope of services includes the following:

Method selection and validation

  • Selection and justification of the appropriate method in accordance with the formulation type and regulatory requirements
  • Standardisation of test conditions (water hardness, temperature, sample volume, application thickness)
  • Validation of the method and verification using reference products
  • Evaluation and reporting of measurement uncertainty
  • Documentation of method-specific limitations and conditions of use

Please feel free to contact Nano-Test for information on the selection of methods, the establishment of standard conditions, sample acceptance criteria, the comparison of specifications, the test plan and the reporting procedures for your wettability tests in accordance with CIPAC MT 53.3.