CIPAC MT 75
CIPAC MT 75, a standardised physico-chemical test method published by the Collaborative International Pesticides Analytical Council (CIPAC) for determining the suspensibility of water-dispersible granules (WG). CIPAC is an international organisation that standardises analytical methods and physico-chemical test procedures for pesticide products; CIPAC methods are widely recognised in pesticide registration dossiers, product specifications and quality control processes.
Hinweis zum regulatorischen Status: CIPAC MT 75 ist ein Verfahren, das in der Vergangenheit zur Bewertung der Suspensionsfähigkeit von wasserzerstreubaren Granulaten verwendet wurde. In der aktuellen Praxis wird für alle Formulierungen, die nach Verdünnung eine Suspension bilden, allgemein die Methode CIPAC MT 184 (Suspensibility of formulations forming suspensions on dilution with water) verwendet. Dennoch wird MT 75 in bestimmten regulatorischen Rahmenwerken weiterhin als Referenz bei der Bewertung bestehender Dossiers und zur Validierung von spezifischen Spezifikationen für WG-Formulierungen herangezogen.
The basic principle of the test is as follows:
- The formulation is dissolved in water of standard hardness at a specific concentration and distributed evenly (by stirring or inverting the container).
- The suspension is left to stand in a standard measuring beaker or cylinder for a specified period (usually 30 minutes).
- Once the waiting period has elapsed, a sample is taken from the upper portion (usually the top 9/10 or a defined volume) and the quantity of material remaining in the lower portion (sediment) is assessed.
- The amount of active ingredient contained in the upper suspension is calculated in relation to the original total amount of active ingredient in order to determine the percentage of suspension (% suspensibility).
- The active substance is usually determined using a formulation-specific analytical method (HPLC, GC, etc.) or, where appropriate, using a gravimetric method.
The basic parameters specified in the study are as follows:
- Suspension capacity (%)
- Test concentration and volume of the suspension prepared
- Water hardness (usually standard hardness, e.g. 342 ppm CaCO₃) and temperature
- Residue time (usually 30 minutes) and extraction depth
- Dispersion method used (stirring speed, duration, number of cycles)
- Method for the determination of the active ingredient and analytical results
- Comparison with the specification value (if available)
- Data on measurement uncertainty and repeatability
Why is this being done?
CIPAC MT 75 is being carried out for the following scientific, technical and regulatory purposes:
- Assessment of product performance: Determination of the ability of the WG formulation to form a homogeneous suspension when diluted with water and to remain in suspension
- Ensuring application quality: providing essential data to ensure that the active ingredient is distributed evenly throughout the tank during spraying and does not precipitate
- Verification of compliance with the product specification: determining whether the suspension capacity meets the specified value (e.g. minimum suspension capacity in %)
- Quality control: Monitoring consistency between production batches and ensuring product quality
- Formulation development: optimising the selection of dispersants, wetting agents and binders; improving the granule structure and dispersion behaviour
- Assessment of storage stability: Monitoring whether the suspension properties are maintained after ageing
- Support with the preparation of authorisation dossiers: use in authorisation dossiers for plant protection products (e.g. EU Regulation 1107/2009, national regulations) and in product specifications
- Approach to assessing evidential value: a contribution to the holistic evaluation of the product in conjunction with other physico-chemical tests (wetting time, dispersion time, sieve test, suspension stability), analytical data and stability studies
CIPAC MT 75 does not, in itself, provide comprehensive information on product quality or biological efficacy. It is intended for the assessment of physico-chemical properties; the results must be interpreted in conjunction with other formulation tests, analytical data, stability studies and the requirements of the specifications.
As part of our nano-testing services, we carry out the suspension tests specified under CIPAC MT 75 with scientific rigour, utilising our accredited laboratory facilities and quality management system. Our scope of services includes the following:
Method selection and validation
- Selection and justification of the appropriate method (CIPAC MT 75 or the current general method CIPAC MT 184) in accordance with the formulation type and regulatory requirements
- Selection, calibration and validation of the formulation-specific method for determining active ingredients (HPLC, GC, etc.)
- Validation of the method: linearity, accuracy, repeatability and reproducibility
- Evaluation and reporting of measurement uncertainty
- Documentation of method-specific limitations and conditions of use
If you require information on method selection, analytical strategy, sample acceptance criteria, specification comparison, test plans and reporting procedures for your suspension capacity tests in accordance with CIPAC MT 75, please do not hesitate to contact Nano-Test.