CIPAC MT 36

CIPAC MT 36, a standard published by the Collaborative International Pesticides Analytical Council (CIPAC) for physico-chemical test methods to determine emulsion stability (emulsion stability) and re-emulsification behaviour following dilution with water. CIPAC is an international organisation that standardises analytical methods and physico-chemical test procedures for plant protection products; CIPAC methods are widely recognised in plant protection product authorisation dossiers, product specifications and quality control processes.

The current versions of the method are known as MT 36.1, MT 36.2 and MT 36.3; there are differences between the versions in terms of sample volume, dilution ratio and evaluation parameters. The core of the method involves diluting the EC formulation with water of standardised hardness and evaluating the behaviour of the emulsion over time, both visually and by measurement.

Emulsion stability is the ability of the EC formulation to remain a homogeneous emulsion after dilution with water. If the emulsion is unstable, cream and free oil form. Re-emulsification is the ability to restore the precipitated or separated phase to a homogeneous emulsion by gentle stirring after a standing time of 24 hours.

The basic principle of the test is as follows:

  • The EC formulation is diluted in water of standard hardness (usually 342 ppm CaCO₃) to the concentration specified in the product specification.
  • The diluted emulsion is left to stand in a standard measuring beaker or cylinder at a specific temperature (usually 30 °C).
  • The emulsion is assessed after 0.5 hours, 2 hours and 24 hours; cream is noted in the upper phase, whilst free fat or the degree of separation (in ml or %) is noted in the lower phase.
  • After 24 hours, the emulsion is gently mixed (e.g. by turning it upside down 10 times) and its ability to re-emulsify is assessed.
  • The results are compared with the limit values specified in the product specification.

The key parameters reported in the study are as follows:

  • Dilution, concentration and volume of the emulsion produced
  • Water hardness and temperature (°C)
  • Amount of cream (ml or %) and free fat content (ml or %)
  • Observations at 0.5 hours, 2 hours and 24 hours
  • Result of re-emulsification (whether or not the product became homogeneous again)
  • Other observed signs of separation (cloudiness, sediment, a film on the surface, etc.)
  • Comparison with the specification value (if available)
  • Data on measurement uncertainty and repeatability

What is the purpose of the test?

CIPAC MT 36 is being carried out for the following scientific, technical and regulatory purposes:

  • Assessment of product performance: Determination of the ability of the EG formulation to form a stable emulsion when diluted with water and to maintain that emulsion
  • Ensuring application quality: assessment of the risk of phase separation, cream formation and the accumulation of free fat in the spray tank
  • Verification of compliance with the product specification: determining whether the emulsion stability meets the specified values (e.g. maximum degree of cream separation/proportion of free fat)
  • Quality control: Monitoring consistency between production batches and ensuring product quality
  • Formulation development: Optimising the selection of emulsifier systems, solvents and excipients
  • Assessment of storage stability: Monitoring whether the emulsion remains stable after ageing
  • Assessment of hard water compatibility: Investigation of emulsion behaviour at different levels of water hardness
  • Support with the preparation of authorisation dossiers: use in pesticide authorisation dossiers (e.g. EU Regulation 1107/2009, national regulations) and product specifications
  • Evidence-based approach: Contribution to the holistic assessment of the product in conjunction with other formulation tests (emulsion formation, dilution stability, foaming, pH, viscosity), analytical data and stability studies

CIPAC MT 36 does not, in itself, provide comprehensive information on product quality or biological efficacy. It enables a physico-chemical performance assessment; the results should be interpreted in conjunction with other formulation tests, analytical data, stability studies and specification requirements.

As part of our nano-testing services, we carry out the emulsion stability and re-emulsification tests specified in CIPAC MT 36 with scientific rigour, utilising our accredited laboratory facilities and quality management system. Our scope of services includes the following:

Method selection and validation

  • Selection and justification of the appropriate version of the method (MT 36.1, MT 36.2 or MT 36.3) in accordance with the wording and regulatory requirements
  • Standardisation of test conditions (water hardness, temperature, dilution ratio, holding times)
  • Validation of the method and verification using reference products
  • Evaluation and reporting of measurement uncertainty
  • Documentation of method-specific limitations and conditions of use

For information on selecting the method version, defining standard conditions, sample acceptance criteria and specification comparison, the test schedule and the reporting procedures for your emulsion stability and re-emulsification tests in accordance with CIPAC MT 36, please feel free to contact Nano-Test.