OECD TG 107

OECD TG 107, OECD Test Guidelines for the Testing of Chemicals, Section 1 (Physicochemical Properties) under ‘Partition coefficient (n-octanol/water): Shaking-flask method’, i.e. partition coefficient (n-octanol/water): shaking-flask method standard. It was first adopted in 1981 and updated in 1995. This is not a test for health effects or ecotoxicity, but a test for determining physicochemical properties.

The partition coefficient (Kow or P) is a measure of the equilibrium distribution of a substance between the n-octanol and aqueous phases and is usually expressed as log Kow (log P). This parameter is a fundamental indicator of the substance’s lipophilicity and is of crucial importance for assessing its bioaccumulative potential, its distribution in the environment and its toxicokinetic behaviour.

OECD TG 107 is a method based on the direct experimental measurement of the partition coefficient and is particularly suitable for substances with low to moderate lipophilicity (approximately log Kow between −2 and 4). The basic principle of the test is as follows:

  • The n-octanol and aqueous phases (usually a buffer solution) are first saturated with each other to avoid interference caused by their mutual solubility.
  • The test substance is dissolved in the aqueous phase (or in both phases); n-octanol is then added.
  • The mixture is shaken until equilibrium is reached (the time taken depends on the substance; usually between a few minutes and 24 hours).
  • Once equilibrium has been reached, the phases are separated by centrifugation or by allowing them to settle.
  • The concentration of the test substance in both phases is determined using a validated analytical method (HPLC, GC, UV-VIS, LC-MS/MS, etc.).
  • The partition coefficient is calculated from the ratio of the concentrations in the two phases: Kow = C(octanol) / C(water).
  • To ensure reliability, the mass balance is checked (to determine how much of the substance originally added is recovered in both phases).

The measurement is usually carried out at a temperature of 25 °C ± 1 °C and in at least three parallel measurements (triplicates). For ionisable substances, the pH value must be checked and, where applicable, the partition coefficient (D) must be stated at the specified pH value.

The basic parameters specified in the study are:

    • log Kow (log P) and the calculated Kow value
    • Measured temperature (°C)
    • pH of the aqueous phase and the buffer used
    • Initial concentration of the test substance and equilibrium concentration in each phase
    • Shaking time and time taken to reach equilibrium
    • Phase ratio (octanol/water volume ratio) and method of phase separation
    • Analytical method used, limit of detection and recovery rate
    • Mass balance (%) and results of parallel measurements
    • Purity and stability

the test substance

  • Data on measurement uncertainty and repeatability

What is the purpose of the test?

OECD Test Category 107 is carried out for the following scientific and regulatory purposes:

  • Direct measurement of lipophilicity: determination of the substance’s fat solubility and its potential to cross cell membranes
  • Assessment of bioaccumulation potential: High log Kow values may indicate a tendency to accumulate in living tissue (BCF estimation)
  • Prediction of distribution in the environment: Prediction of distribution in water, soil, sediment and biota
  • Toxicokinetic assessment: Prediction of absorption, distribution, metabolism and excretion behaviour
  • Analysis of further physico-chemical data: assessment of the substance’s behaviour in the environment, taking into account data on water solubility and adsorption (Koc)
  • Support for regulatory documentation: Use in environmental risk assessments under REACH, for plant protection products, biocides, medicinal products and cosmetics
  • Classification and labelling: Use in the classification of environmental hazards within specific regulatory frameworks
  • Modelling input: Use as a log Kow parameter in environmental fate and transport models
  • Quality control: Monitoring the consistency of the lipophilic behaviour of substances in production processes

OECD TG 107 may not provide reliable results for highly lipophilic substances and surfactants; in such cases, the methods set out in OECD TG 123 (slow-stirring) or, for screening purposes, OECD TG 117 (HPLC) are used. The results should be interpreted taking into account the chemical structure, the state of ionisation, the water solubility and other physicochemical properties of the substance.

As part of our nano-testing services, we carry out partition coefficient measurements in accordance with OECD TG 107, utilising our accredited laboratory facilities and quality management system, and applying scientific rigour. Our scope of services includes the following:

Applicability and validation of the method

  • Assessment of the applicability of TG 107 based on the log Kow range, surface activity, solubility and ionisation properties of the test substance
  • In cases where the method is not applicable, a recommendation and justification for the alternatives TG 123 (slow stirring) or TG 117 (HPLC)
  • Selection, calibration and validation of the analytical measurement method (HPLC, GC, UV-VIS, LC-MS/MS)
  • Validation of the method: linearity, accuracy, recovery, repeatability and inter-repeatability
  • Evaluation and reporting of measurement uncertainty

For information on the applicability of the method, sample preparation and equilibrium strategy, the selection of the analytical method, and sample acceptance criteria, the testing schedule and reporting procedures for your partition coefficient measurements in accordance with OECD TG 107, please feel free to contact Nano-Test.