Hello, how can we help you?

Analysis of primary aromatic amines (PAA) | PPWR

Introduction: The regulatory importance and health risks of primary aromatic amines

Primary aromatic amines (PAA) are organic compounds whose chemical structure contains a primary amino group (-NH₂) directly attached to one or more aromatic rings. This group of substances is of particular regulatory importance for the safety of packaging materials that come into contact with food. PAAs can arise from the breakdown of azo dyes used in packaging production or from incomplete curing reactions of polyurethane-based adhesives. The European Food Safety Authority (EFSA) and the International Agency for Research on Cancer (IARC) have classified many PAA compounds as genotoxic carcinogens. For this reason, Regulation (EU) No 10/2011 of the European Union on plastic materials strictly limits the migration of PAA from plastic materials that come into contact with food to an extremely low level. With the introduction of the PPWR, this control has been further tightened; PAA analyses have become an indispensable part of conformity assessments for packaging manufacturers. Nano-Test Laboratory Services performs PAA analyses using validated LC-MS/MS methods that fully comply with GLP principles; we offer our customers assessments of compliance with legal regulations as well as comprehensive technical consulting.

Chemical structure, sources, and legal framework of PAAs

Primary aromatic amines are not a single chemical compound, but a broad family of substances that share a common structural feature. Within this family, certain compounds have been identified whose names are explicitly listed in Regulation (EU) No 10/2011 and whose migration is prohibited.

Main sources of PAAs in packaging materials

The following table summarizes the reasons for the occurrence of PAAs in packaging materials, their formation mechanisms, and the types of packaging where these mechanisms are typically observed:
Mechanism of formationFormation processTypical packaging type / applicationExplanation
Breakdown of azo dyesCleavage of the nitrogen-nitrogen double bond (N=N)Printed plastic films, colored packaging, paper/cardboard packagingUnder reducing conditions (e.g., in the acidic or reducing environment of food), azo dyes can release PAAs by breaking the azo bond in their structure.
Incomplete curing of polyurethane adhesivesConversion of aromatic isocyanates to PAA upon reaction with waterMulti-layer laminate packaging, flexible films, BagsIf polyurethane adhesives based on aromatic isocyanates are not fully cured, they can undergo hydrolysis when in contact with water and form PAAs (e.g., MDA – methylenedianiline).
Contaminations in raw materialsPAA residues that arise during the production process of monomers or additivesPolymer raw materials, masterbatches, technical additivesSome technical chemicals can contain small amounts of PAA impurities that originate from production processes.
Inks and coatingsBreakdown of pigments and binders used in ink recipesExternally printed packaging, labels, coated cardboardIn particular, the migration of dyes (transfer of the print to the surface of the packaging that comes into contact with food) can lead to PAA contamination.

Important PAA compounds subject to the regulation

Regulation (EU) No 10/2011 lists certain PAA compounds for which the migration from plastic materials that come into contact with food must not be detectable (limit: 0,01 mg/kg food or simulant). The following table shows the most important PAA compounds from this list along with their CAS numbers and typical sources:
Primary aromatic amineAbbreviation / CAS No.Toxicological classificationTypical source / Related azo dye
4,4′-MethylenedianilineMDA / 101-77-9Carcinogen (IARC Group 2B); MutagenPolyurethane adhesives; Isocyanate hydrolysis
BenzidineBZD / 92-87-5Carcinogen (IARC Group 1); genotoxicAzo dyes (based on benzidine); prohibited pigments
2-Naphthylamin2-NA / 91-59-8Carcinogen (IARC Group 1); genotoxicAzo dyes (based on 2-naphthylamine); prohibited pigments
4-Aminobiphenyl4-ABP / 92-67-1Carcinogen (IARC Group 1); genotoxicAzo dyes (based on 4-aminobiphenyl); prohibited pigments
o-Toluidine2-Methylaniline / 95-53-4Carcinogen (IARC Group 1); genotoxicAzo dyes; printing inks
4-Chloranilin4-CA / 106-47-8Suspected of carcinogenicity; MutagenAzo dyes; pigment impurities
AnilineANL / 62-53-3Carcinogen (IARC Group 2A); toxicAzo dyes; a variety of pigments and additives
2,4-Toluenediamine2.4-TDA / 95-80-7Suspected of carcinogenicity; mutagenPolyurethane adhesives; Isocyanate hydrolysis
Note: In Regulation (EU) No 10/2011, the overall migration limit for PAAs is defined as "not detectable", and the analytical detection limit is set at 0.01 mg/kg (per food or simulant). This limit applies to the sum of all listed PAA compounds. Nano-Test can determine more than 20 PAA compounds simultaneously by expanding the analysis scope according to customer needs.

PAA analysis methodology in the Nano-Test laboratory

The analysis of primary aromatic amines is an analytical procedure that requires high sensitivity and selectivity due to the low migration limits of these compounds (0.01 mg/kg). In the Nano-Test laboratory, PAA analyses are performed using LC-MS/MS methods that are optimized and fully validated for these requirements.

Analytical workflow: From migration testing to quantitative determination

The following table describes the entire workflow for PAA analyses in the Nano-Test laboratory:
StepProcedureTechnical Details
1. Experimental planningDefinition of simulants and test conditionsAn appropriate food simulant is selected according to Annexes III and V of Regulation (EU) No 10/2011. The simulant most frequently used for PAA analyses is Simulant B (3 % acetic acid), which represents acidic foods and best simulates the risk of reduction of azo dyes. Simulant A (10 % ethanol) and Simulant C (20 % ethanol) can also be used.
2. Migration testControlled contactThe packaging sample is brought into contact with the selected simulant using standard contact cells or by means of the immersion method at the specified temperature and duration. The test conditions are chosen to reflect the worst-case application scenario.
3. Sample preparationExtraction and purificationThe simulant extract is purified by solid-phase extraction (SPE) or liquid-liquid extraction after appropriate pH adjustment. To ensure the stability of PAA compounds, an antioxidant is added. Matrix effects are corrected by adding isotopically labeled internal standards (e.g., aniline-d5, MDA-d4).
4. LC-MS/MS analysisQuantitative DeterminationAfter separation on a reverse-phase LC column, the purified extract is analyzed using ESI ionization in a triple quadrupole mass spectrometer. For each PAA compound, two MRM transitions are monitored. The LOQ value was validated at ≤ 0.005 mg/kg to enable a reliable assessment of the SML limit of 0.01 mg/kg.
5. Evaluation and ReportingComparison with the SML and declaration of conformityThe quantitative results obtained are compared with the total PAA limit of 0.01 mg/kg. For compounds not detected, the result is reported as “< LOQ”. A comprehensive, GLP-compliant analysis report is generated.

Parameters for quality control and method validation

The following table summarizes the key quality control parameters and acceptance criteria applied for PAA analyses at Nano-Test Laboratory:
Quality Control ParametersFrequency of ApplicationAcceptance criteria
Procedure blankAt least 1 per analysis runAll target PAA compounds < LOQ
Spike recovery in matrixPer run for each simulant type80 % – 120 % recovery
Recovery Rate of Internal StandardAdded to each sample60 % – 140 % recovery
Control standard (mixed PAA solution)At least 1 per analysis runWithin ±20 % of Expected Concentration
Duplicate analysis1 per 10 samplesRelative percent deviation (RPD) ≤ 20 %
Accuracy (recovery)At 3 different concentration levels during validationBetween 80 % and 120 %
Limit of quantification (LOQ)Determined during validation≤ 0.005 mg/kg (SML limit below 0.01 mg/kg)

The integrated service model of Nano-Test for PAA analyses

As Nano-Test Laboratory Services, we do not offer PAA analyses as standalone tests but as an integrated part of the compliance process according to PPWR and 10/2011/EU. Our service model consists of the components summarized in the following table:
Service columnScopeBenefits for the customer
Consultation on regulatory requirementsIdentification of PAA compounds to be analyzed based on the product composition as well as the adhesives and inks used; selection of suitable simulants and test conditionsCost optimization through the right test strategy; avoidance of incomplete or unnecessary analyses
Analytical Testing ServicesGLP-compliant, validated LC-MS/MS method for the simultaneous quantitative determination of more than 20 PAA compoundsAnalysis data accepted by the regulatory authorities, are well-founded and traceable
Conformity assessmentIssuance of a declaration of conformity/non-conformity by comparing the results with the SML limit of 0.01 mg/kg total PAA, resulting in an explanation of conformity or non-conformityA clear and binding assessment of the legal status of the product
Support with technical documentationProvision of a comprehensive analysis report and a declaration of conformity (DOC)Support for the customer in the complete and correct creation of their own declaration of conformity
Consulting in Case of Non-ConformityDetermination of the cause of the problem in the case of exceeding the limit value (glue, ink, pigment or raw material) and recommendations for corrective measuresPermanently eliminating the problem and avoiding recurring non-conformities
Polyurethane adhesives used in multi-layer laminate packaging and azo dyes used in printed packaging are the most common causes of PAA migration. At Nano-Test, we provide more than just analysis data; we also offer our customers technical consulting for analyzing potential sources of detected PAA contamination, optimizing adhesive curing, and selecting alternative raw materials.To ensure that your European market packaging complies with the PAA regulations in accordance with PPWR and 10/2011/EU, and to conduct your analyzes with a reliable and experienced partner, please contact our team of experts for detailed information on the accredited laboratory services and to obtain technical advice from nano-test.

Leave a Reply

Your email address will not be published.

This field is compulsory.

You may use these <abbr title="HyperText Markup Language">html</abbr> tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <s> <strike> <strong>