Hello, how can we help you?

Analysis of Primary Aromatic Amines (PAA) | PPWR

Introduction: The Regulatory Significance and Health Risks of Primary Aromatic Amines

Primary aromatic amines (PAAs) are organic compounds whose chemical structure contains a primary amino group (-NH₂) directly bonded to one or more aromatic rings. This group of substances is of particular regulatory importance for the safety of packaging materials that come into contact with food. PAAs can result from the degradation of azo dyes used in packaging manufacturing or from incomplete curing reactions of polyurethane-based adhesives. The European Food Safety Authority (EFSA) and the International Agency for Research on Cancer (IARC) have classified many PAA compounds as genotoxic carcinogens. For this reason, European Union Regulation (EU) No. 10/2011 on plastic materials strictly limits the migration of PAAs from plastic materials that come into contact with food to an extremely low level. With the introduction of the PPWR, these controls have been further tightened; PAA analyses have become an indispensable part of conformity assessments for packaging manufacturers. Nano-Test Laboratory Services performs PAA analyses using validated LC-MS/MS methods that fully comply with GLP principles; we offer our clients regulatory compliance assessments as well as comprehensive technical consulting.

Chemical Structure, Sources, and Legal Framework of PAAs

Primary aromatic amines are not a single chemical compound, but rather a broad family of substances that share a common structural feature. Within this family, certain compounds have been identified whose names are explicitly listed in Regulation (EU) No. 10/2011 and whose migration is prohibited.

Main Sources of PAAs in Packaging Materials

The following table summarizes the reasons for the presence of PAAs in packaging materials, the mechanisms by which they form, and the types of packaging in which these mechanisms are typically observed:
Mechanism of FormationDevelopment ProcessTypical Packaging Type / ApplicationExplanation
Degradation of azo dyesCleavage of the nitrogen-nitrogen double bond (N=N)Printed plastic films, colored packaging, paper/cardboard packagingUnder reducing conditions (e.g., in the acidic or reducing environment of food), azo dyes can release PAAs by breaking the azo bond in their structure.
Incomplete Curing of Polyurethane AdhesivesConversion of Aromatic Isocyanates to PAA Upon Reaction with WaterMultilayer laminate packaging, flexible films, bagsIf polyurethane adhesives based on aromatic isocyanates have not fully cured, they may undergo hydrolysis upon contact with water, forming PAAs (e.g., MDA—methylenedianiline).
Contaminants in Raw MaterialsPAA residues generated during the manufacturing process of monomers or additivesPolymer raw materials, masterbatches, technical additivesSome industrial chemicals may contain small amounts of PAA impurities that originate from the manufacturing processes.
Printing Inks and CoatingsBreakdown of pigments and binders used in printing ink formulationsExternally printed packaging, labels, coated cardboardIn particular, ink migration (the transfer of the print to the surface of the packaging that comes into contact with food) can lead to PAA contamination.

Important PAA compounds subject to the regulation

Regulation (EU) No. 10/2011 lists certain PAA compounds for which migration from plastic materials that come into contact with food must not be detectable (limit: 0.01 mg/kg of food or simulant). The following table shows the most important PAA compounds on this list, along with their CAS numbers and typical sources:
Primary aromatic amineAbbreviation / CAS No.Toxicological ClassificationTypical source / Related azo dye
4,4′-MethylenedianilineMDA / 101-77-9Carcinogen (IARC Group 2B); MutagenPolyurethane Adhesives; Isocyanate Hydrolysis
BenzidineBZD / 92-87-5Carcinogen (IARC Group 1); genotoxicAzo dyes (benzidine-based); prohibited pigments
2-naphthylamine2-NA / 91-59-8Carcinogen (IARC Group 1); genotoxicAzo dyes (2-naphthylamine-based); prohibited pigments
4-aminobiphenyl4-ABP / 92-67-1Carcinogen (IARC Group 1); genotoxicAzo dyes (based on 4-aminobiphenyl); prohibited pigments
o-toluidine2-Methylaniline / 95-53-4Carcinogen (IARC Group 1); genotoxicAzo dyes; printing inks
4-chloroaniline4-CA / 106-47-8Suspected carcinogen; mutagenAzo dyes; pigment impurities
AnilineANL / 62-53-3Carcinogen (IARC Group 2A); toxicAzo dyes; a wide variety of pigments and additives
2,4-Toluene-1,4-diamine2,4-TDA / 95-80-7Suspected carcinogenicity; mutagenicPolyurethane Adhesives; Isocyanate Hydrolysis
Note: Regulation (EU) No. 10/2011 defines the total migration limit for PAAs as “not detectable,” and the analytical limit of detection is set at 0.01 mg/kg (per food or simulant). This limit applies to the sum of all listed PAA compounds. By expanding the scope of analysis to meet customer needs, Nano-Test can simultaneously determine more than 20 PAA compounds.

PAA Analysis Methods in the Nano-Test Laboratory

The analysis of primary aromatic amines is an analytical method that requires high sensitivity and selectivity due to the low migration limits of these compounds (0.01 mg/kg). At the Nano-Test laboratory, PAA analyses are performed using LC-MS/MS methods that have been optimized and fully validated to meet these requirements.

Analytical Workflow: From Migration Testing to Quantitative Analysis

The following table describes the entire workflow for PAA analyses in the Nano-Test laboratory:
StepProcedureTechnical Details
1. Experimental DesignDetermination of Simulants and Test ConditionsA suitable food simulant is selected in accordance with Annexes III and V of Regulation (EU) No. 10/2011. The simulant most commonly used for PAA analyses is Simulant B (3% acetic acid), which represents acidic foods and best simulates the risk of azo dye reduction. Simulant A (10% ethanol) and Simulant C (20% ethanol) may also be used.
2. Migration TestControlled ContactThe packaging sample is exposed to the selected simulant at the specified temperature and for the specified duration, either using standard contact cells or by the immersion method. The test conditions are selected to reflect the most adverse application scenario.
3. Sample PreparationExtraction and PurificationAfter adjusting the pH as appropriate, the simulant extract is purified using solid-phase extraction (SPE) or liquid-liquid extraction. An antioxidant is added to ensure the stability of the PAA compounds. Matrix effects are corrected by adding isotopically labeled internal standards (e.g., aniline-d5, MDA-d4).
4. LC-MS/MS AnalysisQuantitative DeterminationAfter separation on a reverse-phase LC column, the purified extract is analyzed using ESI ionization in a triple-quadrupole mass spectrometer. Two MRM transitions are monitored for each PAA compound. The LOQ was validated at ≤ 0.005 mg/kg to enable a reliable assessment of the SML limit of 0.01 mg/kg.
5. Analysis and ReportingComparison with the SML and Declaration of ConformityDie erhaltenen quantitativen Ergebnisse werden mit dem Gesamt-PAA-Grenzwert von 0,01 mg/kg verglichen. Für nicht nachgewiesene Verbindungen wird das Ergebnis als „< LOQ“ angegeben. Es wird ein umfassender, GLP-konformer Analysebericht erstellt.

Parameters for Quality Control and Method Validation

The following table summarizes the most important quality control parameters and acceptance criteria used for PAA analyses at the Nano-Test laboratory:
Quality Control ParametersFrequency of useEligibility Criteria
Procedural Blind TestAt least 1 per analysis runAlle Ziel-PAA-Verbindungen < LOQ
Recovery Rate When Matrix Is AddedPer run for each type of simulated patient80%–120% recovery rate
Recovery rate of the internal standardAdded to each sample60% – 140% recovery
Control standard (mixed PAA solution)At least 1 per analysis runWithin ±20% of the expected concentration
Double Analysis1 out of every 10 samplesRelative Percent Deviation (RPD) ≤ 20%
Accuracy (Recovery)At 3 different concentration levels during validationBetween 80% and 120%
Limit of Detection (LOQ)Determined during validation≤ 0.005 mg/kg (SML limit below 0.01 mg/kg)

Nano-Test's Integrated Service Model for PAA Analysis

At Nano-Test Laboratory Services, we do not offer PAA analyses as standalone tests, but rather as an integral part of the conformity assessment process in accordance with PPWR and 10/2011/EU. Our service model consists of the components summarized in the following table:
Services ColumnScopeBenefits for the Customer
Consulting on Regulatory RequirementsIdentification of the PAA compounds to be analyzed based on product composition and the adhesives and printing inks used; selection of appropriate simulants and test conditionsCost optimization through the right testing strategy; avoiding incomplete or unnecessary analyses
Analytical Testing ServicesGLP-compliant, validated LC-MS/MS method for the simultaneous quantitative determination of more than 20 PAA compoundsAnalytical data that is accepted by regulatory authorities and is well-founded and traceable
Conformity AssessmentIssuance of a declaration of conformity or nonconformity by comparing the results with the SML limit of 0.01 mg/kg total PAA, resulting in a declaration of conformity or nonconformityA clear and definitive assessment of the product's legal status
Support for Technical DocumentationProvision of a comprehensive analysis report and a Declaration of Conformity (DoC)Assisting the customer in preparing their own declaration of conformity completely and correctly
Advice on NonconformityIdentification of the root cause of issues when limit values are exceeded (adhesive, printing ink, pigment, or raw material) and recommendations for corrective actionsPermanently resolving the problem and preventing recurring nonconformities
Polyurethane adhesives used in multilayer laminate packaging and azo dyes used in printed packaging are the most common causes of PAA migration. At Nano-Test, we provide more than just analytical data; we also offer our customers technical consulting on identifying the causes of potential sources of detected PAA contamination, optimizing adhesive curing, and selecting alternative raw materials.To ensure that your packaging intended for the European market complies with PAA regulations as set forth in the PPWR and Directive 10/2011/EU, and to have your analyses conducted by a reliable and experienced partner, please contact our team of experts to receive detailed information about Nano-Test’s accredited laboratory services and technical consulting.