OECD TG 102

OECD TG 102 is the standard ‘Melting Point/Melting Range’, i.e. melting point/melting range, which is listed under Section 1 (Physico-chemical Properties) of the OECD Test Guidelines for the Testing of Chemicals. This is not a test for health effects or ecotoxicity, but rather a test of physicochemical properties.

The melting point is defined as the temperature at which a substance changes from a solid to a liquid state. The melting range, on the other hand, is the range between the temperature at which the substance begins to melt and the temperature at which it is completely molten. In the case of pure substances, melting generally takes place within a narrow temperature range, whilst the melting range widens and the melting point decreases as the level of impurity increases.

The basic principle of the test is to determine the melting behaviour of the test substance in the solid state under controlled heating conditions. OECD TG 102 does not prescribe any specific method, but permits the use of suitable and validated methods.

What is the purpose of the examination?

OECD TG 102 is being carried out for the following scientific and regulatory purposes:

  • Substance identification: The melting point is a characteristic physico-chemical property of a pure substance and serves as a reference value for confirming the identity of the substance

Purity assessment: The width of the melting range and a lowering of the melting point provide information about impurities

Physico-chemical characterisation: Documentation of the substance’s basic physico-chemical profile in regulatory dossiers

Input for further tests: The physical state of the substance at room temperature (solid/liquid) influences the design and conduct of further tests

Classification for transport and storage: The melting point is used for classification and labelling in connection with the transport and storage of chemicals

Quality control: Monitoring the consistency of raw materials, intermediate products and finished products in production processes

Weight of evidence approach: Contributes, together with other physico-chemical, toxicological and environmental data, to the holistic assessment of the substance

OECD TG 102 does not, in itself, constitute a toxicity or hazard assessment. It is intended for physicochemical characterisation; the results must be interpreted in conjunction with other physicochemical properties, toxicological data and an exposure assessment.

As part of our nano-testing services, we determine the melting point and melting range in accordance with OECD TG 102, applying scientific rigour and utilising our accredited laboratory facilities and quality management system. Our scope of services includes the following:

Method selection and validation

  • Selection of the appropriate method (capillary, heated microscope, DSC) in accordance with the properties of the test substance and regulatory requirements
  • Validation of the selected method and verification using suitable reference substances
  • Evaluation and reporting of measurement uncertainty
  • Documentation of method-specific limitations and conditions of use

Please feel free to contact Nano-Test for information on the choice of methods, sample acceptance criteria, the test plan and the reporting procedures for your melting point and melting range determinations in accordance with OECD TG 102.