EN 1186-3

EN 1186-3 – The full title of this standard is: ”Materials and articles in contact with foodstuffs – Plastics – Part 3: Test methods for overall migration into aqueous food simulants by total immersion”
by total immersion in aqueous food simulants”.

EN 1186-3 defines test methods for determining the total amount of non-volatile substances released from plastic materials intended for food contact into aqueous food simulants, using the total immersion method (Total Immersion). The standard contains various procedures that vary depending on sample geometry and the type of contact. Method 1 is the basic method in which the sample is completely immersed in the simulant in a specified volume and is based on gravimetric residue measurement after contact.

This procedure is particularly suitable for samples such as films, sheets, coatings, small parts, and samples with single- or multi-sided contact that can be represented by complete immersion. The selection of the method is made taking into account the EN 1186-1 guideline and applicable legal requirements, so that the actual conditions of use of the sample are reflected.

Scientific basis of Method 1

Within the scope of EN 1186-3 Method 1, overall migration is based on the gravimetric determination of the total mass of non-volatile substances that migrate from the plastic material into an aqueous simulant under specific temperature and time conditions. The general test procedure follows this principle:

  1. The surface of the sample that comes into contact with food is measured and recorded.
  2. The sample is completely immersed in an aqueous food simulant with a specified volume.
  3. The sample is brought into contact with the simulant for the temperature and time specified in the standard and the product's conditions of use.
  4. After contact, a specific portion of the simulant is evaporated or dried under suitable conditions.
  5. The remaining non-volatile residue is weighed on an analytical balance.
  6. The same procedure is carried out for the simulant as a blank test.
  7. The overall migration value is calculated taking the blank correction into account.

Food simulants used

Since EN 1186-3 is a standard for aqueous food simulants, aqueous simulants representing the type of food with which the product comes into contact are used within the scope of Method 1. In practice, the following simulants are primarily used:

  • Simulant A: Distilled water or water of equivalent quality (aqueous foods),
  • Simulant B: 3% (w/v) acetic acid (foods with a pH of 4.5 and below),
  • Simulant C: 10% (v/v) ethanol (alcoholic and aqueous foods),
  • Other aqueous simulants defined in relevant legislation according to the conditions of use of the product.

The choice of simulant is made taking into account the food structure, pH value, alcohol content, as well as contact temperature and duration. Simulants representing fatty foods do not fall within the scope of this standard; in these cases, the corresponding other parts of the EN 1186 series of standards apply.

Why is EN 1186-3 Method 1 performed?

  • Legal Conformity: Demonstration of conformity of plastic food contact materials with the overall migration limits in accordance with EU Regulation 10/2011 and relevant national legislation.
  • Food Safety: Control of the total amount of non-volatile substances that can migrate from products coming into contact with aqueous foods into the food.
  • Risk Assessment: Determination of the overall migration potential of raw materials, additives, oligomers, and process-related residues.
  • Product Development: Evaluation of the migration behavior of new formulations, coatings, films, and multilayer structures in aqueous media.
  • Quality control: Monitoring consistency between production batches and evaluating the impact of process changes.
  • Supply Chain and Export: Provision of test data for declarations of conformity, technical documentation, and customer specifications.
In our laboratory, we offer the following services within the scope of EN 1186-3 Method 1:
  • Justification of the test design and method selection according to the conditions of use of the product,
  • Sample preparation and determination of the surface area coming into contact with food,
  • Selection of an aqueous food simulant and planning of test conditions in accordance with EN 1186-1,
  • Execution of the overall migration test by total immersion under controlled conditions,
  • Evaporation/drying of the simulant and gravimetric residue measurement,
  • Correction and calculation of the control test,
  • Technical report in accordance with legal regulations and customer requirements.

Test procedure

  1. Inquiry and Preliminary Assessment: Product description, type of food contact, application temperature and duration are evaluated.
  2. Sample Receipt: Shape, thickness, surface area, and homogeneity of the sample are recorded.
  3. Test Plan: Simulant, temperature, duration, simulant volume, and immersion device are determined.
  4. Migration: The sample is completely immersed in the simulant under controlled conditions and brought into contact with it.
  5. Residue Preparation: A specific portion of the simulant is evaporated under suitable conditions and prepared for weighing.
  6. Gravimetric Measurement: The masses of the sample and reference residues are measured on an analytical balance.
  7. Calculation: Taking the reference correction into account, the overall migration value is calculated.
  8. Reporting: The test conditions, results, evaluation of limit values, and uncertainty are included in the report.
In our laboratory, we carry out the processes of test planning, sample preparation, migration testing, gravimetric measurement, calculation, and reporting in this context in accordance with the standard document, the requirements of the quality management system, and the applicable legal regulations for food contact. You are welcome to contact our technical team for the overall migration testing of your product in accordance with EN 1186-3, Method 1.